Landfill Base and Capping
Specify a liner as part of the designed barrier assembly, with drainage, protection and construction quality assurance.
Source smooth or textured HDPE geomembrane rolls for landfill, mining and water-containment systems. Specify thickness, surface finish, panel size and test requirements for a project quotation.
For project-specific pricing, send your technical requirements and destination port.
This roll liner is intended for welded containment assemblies. Start the RFQ with the application, thickness and surface finish, then specify mechanical and durability indices. The 1.5 mm smooth-sheet figures above give buyers a comparable starting schedule; they are not a substitute for the offered grade’s current technical data and project quality records.
Smooth sheet is often used across prepared base areas. On slopes, a textured interface may be needed to meet a project-specific shear requirement. Texture selection should follow the actual soil, geotextile and cover interfaces; smooth-sheet tensile and puncture figures should not be copied into a textured-grade schedule.
Roll width can reduce the number of field seams, but handling access, panel layout and container limits also matter. Send the site drawings and quantity together with required seam testing, protective geotextile, welding accessories and roll documentation. This produces a quotation the contractor can relate to the installed barrier, not just the sheet area.
Specify a liner as part of the designed barrier assembly, with drainage, protection and construction quality assurance.
Use in engineered heap-leach, tailings or process-water systems after reviewing chemical compatibility and slope stability.
Line reservoirs, irrigation ponds and channels where hydraulic loading, anchorage and exposure conditions are defined.
Provide a welded barrier beneath or around facilities where the retained liquid and site details are known.
Welded HDPE panels form the primary low-permeability layer of a specified containment system.
Select surface finish against the actual interface shear requirement; textured and smooth sheets have different technical indices.
Tensile, tear and puncture targets help buyers compare proposed grades for handling and installed loads.
Request formulation-related indices such as carbon black, stress-crack resistance and oxidative induction time for the selected grade.
1.5 mm smooth HDPE procurement index. Specify the offered grade, agreed test methods and roll test documentation in the purchase schedule; textured grades need a separate index.
| Test Item | Unit | Test Method | Requirement | Result / Notes |
|---|---|---|---|---|
| Nominal thickness | mm | ASTM D5199 | 1.5 | Smooth reference grade; confirm tolerance |
| Formulated sheet density | g/cm³ | ASTM D1505 / D792 | ≥0.940 | Reference minimum |
| Tensile strength at yield | kN/m | ASTM D6693 Type IV | ≥22 | Both machine and cross directions |
| Tensile strength at break | kN/m | ASTM D6693 Type IV | ≥40 | Both machine and cross directions |
| Elongation at break | % | ASTM D6693 Type IV | ≥700 | Smooth-sheet reference |
| Tear resistance | N | ASTM D1004 | ≥190 | Smooth-sheet reference |
| Puncture resistance | N | ASTM D4833 | ≥480 | Smooth-sheet reference |
| Carbon black content | % | ASTM D4218 / agreed method | 2.0–3.0 | Black formulation reference |
| Stress-crack resistance | hours | ASTM D5397 Appendix | ≥500 | Request offered-grade test record |
| Oxidative induction time | min | Agree standard or high-pressure OIT method | ≥100 standard or ≥400 high-pressure | Specify one accepted route in the RFQ |
Swipe to view the full table →
Approve a compact, smooth subgrade and the specified protective geotextile before liner deployment.
Set panel direction, slope details, anchor trenches and thermal movement allowance in the installation plan.
Qualify welding settings for site conditions; use double-track hot-wedge seams where applicable and extrusion welds for details.
Use the approved air-channel, vacuum-box and destructive seam tests. Control traffic, drop height and cover placement after acceptance.
State thickness, finish, width, length and total area so quoted rolls match the panel layout.
Confirm roll weight, core, lifting method, wrapping and container fit for the selected grade.
Request roll identification and the grade-specific manufacturing and test records required by the project.
List welding rod, trial panels and any geotextile protection as separate quotation items.
Request via contact form
Request via contact form
Leave a quick message regarding your project needs, and our team will get back to you shortly.
+86 15263640998
Email Inquiry