Basements, Tunnels, Underground Structures
PU's ≥550% elongation absorbs concrete shrinkage without cracking. 0.3 MPa watertightness handles significant hydrostatic head. Apply to damp formwork-stripped concrete — no waiting for full curing.
Factory Direct Supply
TY-SHIELD™ single-component polyurethane waterproof coating — a moisture-curing, liquid-applied waterproofing membrane. No on-site mixing, no pot-life countdown, no catalyst. Open the drum and apply; the coating absorbs atmospheric moisture and cures into a seamless, highly elastic rubber membrane. Available in Type I (≥550% elongation, for movement joints) and Type II (≥2.45 MPa tensile, for hydrostatic pressure). Applies to damp substrates and bonds to concrete, masonry, metal, wood, and glass. Standard formulation is aromatic; aliphatic (UV-resistant) variants available for exposed roofs on request. Compliant with GB/T 19250-2013.
For project-specific pricing, send your technical requirements and destination port.
A basement slab with three pipe penetrations converging at one corner, a drainage channel running diagonally, and an elevator pit with compound-angle inside corners. A 1-meter-wide SBS modified bitumen membrane installer cuts seven or eight separate pieces to fit this single detail — each lap seam is a potential leak path.
PU does not cut and fit. It is a liquid. Pour it in, spread it, and it self-levels into the lowest point, filling annular spaces around pipes and rounding inside corners naturally. The cured film is one continuous, seamless elastomeric membrane — chemically formed on the substrate, not mechanically assembled from factory-cut pieces. Installation time at complex nodes is typically one-third or less of the equivalent sheet membrane detailing.
Weifang Tianyuan supplies PU waterproof coating direct from the production line. Specify the type, volume, application, and destination port; our team can then confirm the applicable quotation, production schedule, container configuration, freight options, and available custom variants.
PU's ≥550% elongation absorbs concrete shrinkage without cracking. 0.3 MPa watertightness handles significant hydrostatic head. Apply to damp formwork-stripped concrete — no waiting for full curing.
Roller or spray for large areas, hand scraper for details. PU stays in place on sloped and vertical surfaces. For exposed roofs, specify the aliphatic formulation — passes GB/T 19250 artificial weathering.
2–3 coats at 0.8–1.0 kg/m² each. Broadcast sand into the final wet coat — tile adhesive bonds directly, no separate primer needed.
The most frequent leak points in any system. PU fills the annular space in one pass — no cutting, no laps. Cures into a monolithic seal around every penetration.
Polyether-based PU resists hydrolytic degradation far better than polyester-based alternatives — the ether linkage (C–O–C) is inherently stable in water. This is why TY-SHIELD™ is specified for swimming pools, water tanks, and permanently submerged applications. Type II retains 80–150% of tensile strength after alkali treatment per GB/T 19250.
Sheet membranes arrive at fixed gauge; you can't adjust. PU thickness is controlled by the applicator: 1 mm dry film ≈1.6–1.8 kg/m². 1.5 mm for roofs, 2 mm for pools, 2.5 mm for high-water-table basements — same drum, just more passes.
GB/T 19250 requires all types to pass -40°C bend with no cracking. Most elastomeric coatings turn brittle below freezing; PU's polymer network stays flexible. For northern China, Russia, and Scandinavia, this determines whether waterproofing survives its first winter.
Pull-off testing fractures the concrete, not the bond line. Under hydrostatic pressure, water cannot peel the coating off — it would need to tear the concrete apart. PU achieves this through covalent bonding between isocyanate groups and substrate hydroxyl groups at the molecular level.
Single-Component PU / Type I & II / GB/T 19250-2013
| Test Item | Unit | Test Method | Requirement | Result / Notes |
|---|---|---|---|---|
| Tensile Strength — Type I | MPa | GB/T 19250 | ≥ 1.9 | ≥ 1.9 |
| Tensile Strength — Type II | MPa | GB/T 19250 | ≥ 2.45 | ≥ 2.45 |
| Elongation at Break — Type I | % | GB/T 19250 | ≥ 550 | 550+ |
| Elongation at Break — Type II | % | GB/T 19250 | ≥ 450 | 450+ |
| Tear Strength — Type I | N/mm | GB/T 19250 | ≥ 12 | ≥ 12 |
| Tear Strength — Type II | N/mm | GB/T 19250 | ≥ 14 | ≥ 14 |
| Low Temp Flexibility | °C | GB/T 19250 | -40°C — No crack | No crack |
| Watertightness | MPa / min | GB/T 19250 | 0.3 MPa, 30 min | Watertight |
| Solid Content | % | GB/T 19250 | ≥ 80 | ≥ 80 |
| Damp-Base Adhesion | MPa | GB/T 19250 | ≥ 0.50 | ≥ 0.50 |
| Heat/Alkali/Acid — Tensile Retention (Type II) | % | GB/T 19250 | 80–150 | Typical value; confirm with the product TDS |
| Artificial Weathering | — | GB/T 19250 | No crack or deformation | No crack |
Swipe to view the full table →
Values shown apply to the stated product configuration. For aliphatic (UV-resistant) formulations, solvent-free variants, or custom performance targets, request the corresponding TDS and batch test report. Current standard: GB/T 19250-2013. A revised national standard (project no. 20253698-T-609) is under development by SAC/TC 195. Contact our technical team for ASTM equivalence cross-reference data.
Remove loose material, dust, and oil. Grind down high spots. Fill cracks wider than 2 mm with repair mortar. The substrate can be damp — dark in color, cool to the touch — but there must be no standing water. For basements, pump out any pooled water and allow 24 hours of ventilation before application. No primer is required on sound concrete.
Apply 2–4 extra coats at all inside and outside corners, pipe penetrations, and floor drains before the main area. Build thickness to ≥1 mm at these points. If reinforcement fabric is specified, embed polyester non-woven fabric into the wet coating at this stage — press firmly with a scraper to fully saturate the fabric and eliminate air pockets.
Apply the first coat in one direction using a rubber squeegee or short-nap roller. Wait until tack-free — approximately 4–6 hours at 25°C, longer below 15°C. Apply the second coat perpendicular to the first. The cross-direction pattern seals pinholes that may have formed in the first coat. Each coat consumes approximately 0.8–1.0 kg/m². Total film thickness depends on the application: 1.2 mm for bathrooms, 1.5 mm for roofs, 2 mm minimum for pools and basements.
For crack-repair zones, cold joints, and new-to-old concrete interfaces, lay glass-fiber mesh or polyester non-woven fabric into the first coat while it is still wet. Press from the center outward with a scraper to expel all trapped air. The fabric must be fully saturated — no dry fibers visible on the surface. Overlap adjacent fabric sections by at least 100 mm.
The prepolymer cures on contact with air. Every drum is moisture-sealed with a rubber-gasketed lid. 10 kg, 20 kg, 25 kg. Palletized for container shipment.
Flammable liquid, Packing Group III. Drums must remain upright. MSDS required for DG container booking. TDS, MSDS, packing list, and certificate of origin provided with every shipment.
Store at 5–40°C, dry and ventilated. Reseal opened drums within 30 minutes — air in the headspace reacts with the product. Expired drums: remove surface skin, stir, test-patch. If it cures tack-free in 24h, it's still usable.
Custom label, drum color, and size. Formulation-level tuning: lower viscosity for spray, thixotropic additive for vertical surfaces, faster tack-free for humid climates, aliphatic base for UV-exposed product positioning. Sample batch for approval before production.
Ready for PDF Request
Ready for PDF Request
Leave a quick message regarding your project needs, and our team will get back to you shortly.
+86 15263640998
Email Inquiry