Quick specifications

Standard
GB 12952-2011 / ASTM D4434
Type Options
H (Homogeneous), P (Reinforced), L (Fleece-backed), G (Glass fiber)
Thickness
1.2mm, 1.5mm, 1.8mm, 2.0mm
Width
2.05m / 1.0m
Service Life
Project-specific; confirm with the product TDS

Product overview

Why Choose PVC for Critical Engineering?

PVC waterproofing membranes are the smart choice for modern infrastructure. Unlike traditional bitumen products, PVC remains flexible for decades and uses thermoplastic welding to create an inseparable bond. At Tianyuan Waterproof, we ensure our PVC meets global engineering standards for durability and environmental resistance.

1. Internal Reinforced Structure (The Secret of Strength)

The reliability of a PVC membrane starts from within. Our Type P (Reinforced) series is engineered with a high-tenacity polyester fabric core.

  • Internal Polyester Scrim: Acts as the “skeleton” of the membrane, preventing stretching and providing exceptional tear resistance.
  • UV-Resistant Top Layer: Specifically formulated to reflect solar heat (Cool Roof effect) and resist degradation from long-term UV exposure.
  • Durable Bottom Layer: Optimizes adhesion to various substrates while maintaining overall sheet flexibility.

PVC Internal Structure Schematic


2. High-Precision Installation: Monolithic Seams

The weakest point of any waterproofing system is usually the joint. PVC solves this through Hot-Air Welding. Hot-air welding joins compatible overlapping sheet surfaces. Establish the equipment settings through trial welds and follow the supplied installation and seam inspection requirements.

  • No Adhesives Needed: Unlike EPDM or bitumen, the joint itself becomes the strongest part of the system.
  • Automatic Welding: Our membranes are designed for high-speed automatic welding machines (like Leister), ensuring consistent quality across large-scale projects.
  • Continuous Welded Seams: Once cooled, a properly executed seam forms a continuous connection. Weld settings, substrate preparation, and seam testing must follow the project installation requirements.

PVC Hot-Air Welding Process


3. Integrated System Solutions: Accessories & Parts

A professional project requires more than just a roll of membrane. Tianyuan offers a complete accessory matrix to handle complex architectural details. Using prefabricated parts reduces labor costs and eliminates human error at corners and drains.

  • Prefabricated Corners: Pre-molded inside and outside corners for 90-degree transitions.
  • Mechanical Fasteners: Specialized screws and stress plates for wind-resistant steel roof systems.
  • Roof Drains & Vents: PVC-compatible outlets designed to weld to the main membrane. Detail design and seam testing should follow the project waterproofing system requirements.

Select PVC-compatible welded accessories for the specified PVC sheet. Our TPO roofing membrane systems require their own compatible components. PVC and TPO must not be welded directly to each other; transitions require an approved detail.

PVC Waterproofing System Accessories


4. Proven Performance: Global Project Showcases

From 50,000 sqm industrial plants to complex metro tunnel linings, our PVC membranes have been proven in the field.

  • Industrial Cool Roofs: Confirm the exact white membrane’s measured solar reflectance, thermal emittance and any required SRI value. Building energy effects depend on climate, insulation, operation and the complete roof design.
  • Tunnel & Subway: Our H-type (homogeneous) membranes provide reliable anti-seepage for high-pressure underground environments. See our technical documentation for project-specific waterproofing system design.
  • Green Roofs: Inherent root resistance makes PVC the primary choice for sustainable rooftop gardens.

Industrial PVC Roofing Project Overview


5. Technical Comparison: Choosing Between H, P, L, and G Types

TypeNameStructureTypical Application
Type HHomogeneousPure PVC sheetTunnels, underground, and detail applications
Type PReinforcedInternal Polyester ScrimExposed roofing (Mechanically Fastened)
Type LFleece-backedFabric/Fleece BackingFully Adhered systems and renovations
Type GGlass FiberInternal Glass FiberSystems requiring enhanced dimensional stability

Applications

Industrial Flat Roofs

Exposed mechanically-fastened systems for factories, warehouses, and commercial buildings.

Tunnel & Metro

PVC-P geomembrane blind-side lining for bored and cut-and-cover tunnels.

Green Roof & Plaza Decks

Root-resistant membrane beneath vegetated layers and pedestrian pavers.

Basement & Foundation

Below-grade tanking for deep excavations and retaining walls.

Swimming Pools & Water Features

Welded PVC lining for concrete pools, fountains, and reflecting ponds.

Key benefits

Cool Roof Reflective Surface

White PVC roofing options can help reduce solar heat gain. Request measured solar reflectance and thermal emittance for the proposed configuration, and an SRI result if required. These metrics are distinct and do not by themselves establish building energy savings.

Root-Proof for Green Systems

Naturally resistant to root penetration without the need for additional biocides, making it the premier choice for vegetated roof gardens and landscaped podium decks in modern urban architecture.

Adaptive Low-Temp Workability

Maintains its flexibility and detailing capability in temperatures down to -25°C, ensuring that installation can proceed safely and reliably during winter months without the risk of membrane cracking.

Total Accessory Ecosystem

Supported by a full range of prefabricated corners, pipe boots, and drain flashings. These factory-molded components eliminate the variables of field fabrication and ensure uniform security across the entire project.

Technical specifications

Technical specifications of PVC Waterproofing Membrane
Test Item Unit Test Method Requirement Result / Notes
Tensile Strength MPa GB12952 >= 10 12-14 MPa
Elongation at Break % GB12952 >= 200 (Type H) 250%+
Low Temp Flexibility °C GB12952 No crack at -25 Typical value; confirm with the product TDS
Puncture Resistance N FTM 101C High Load Typical value; confirm with the product TDS
Tear Resistance N/mm GB12952 >= 50 55-65
Dimensional Stability % GB12952 ≤ 2.0 (80°C) ≤ 1.5
Watertightness MPa GB12952 0.3 MPa, 2h No Leakage
Heat Aging (Tensile Retention) % GB12952 ≥ 90 (80°C, 168h) ≥ 92
Joint Peel Strength N/50mm GB12952 >= 40 45-55
Solar Reflectance (White) Dimensionless fraction Confirm the test method in the product report As specified by the project Request product-specific measured results

Swipe to view the full table →

Installation & documents

View documents ↓

Installation method

Confirm by configuration

Substrate / application

Use a clean, sound and compatible substrate or application surface.

Key requirement

Follow the selected configuration's TDS for preparation, conditions and detailing.

Refer to the applicable product TDS for substrate preparation, application conditions and detailing requirements.

Technical downloads

PVC Technical Data Sheet (TDS)

Request via contact form

Request PDF

Roofing System Manual

Request via contact form

Request PDF

Related product

Frequently asked questions

What is PVC waterproofing membrane and how is it different from TPO?
PVC (polyvinyl chloride) waterproofing membrane is a single-ply thermoplastic sheet that can be supplied with internal polyester reinforcement. Compared with TPO, PVC formulations and project suitability differ in flexibility, chemical resistance, welding behavior, environmental profile, and fire performance. Compare the product-specific TDS with the project requirements before selection.
Is PVC membrane good for flat roofs, and how thick should it be?
Yes, PVC membrane is widely used on flat and low-slope commercial roofs. For exposed mechanically-fastened systems, 1.5 mm (60 mil) is the standard thickness; for high-traffic or fully adhered applications, 1.8-2.0 mm (72-80 mil) is recommended. The membrane's hot-air welded seams create a monolithic barrier that performs reliably even under ponding water conditions.
How do you install and weld PVC waterproofing membrane?
Use the attachment method and compatible components specified for the roof assembly. Prepare clean, dry weld surfaces and establish temperature, speed and airflow through trial welds with the supplied membrane and actual site conditions. Follow the applicable seam inspection and testing procedure rather than relying on a fixed equipment temperature.
Can PVC membrane be installed over existing bitumen roofing?
Yes, PVC membrane can be installed as a retrofit over existing bitumen roofing, but a separation layer (geotextile fleece or gypsum board) must be placed between the bitumen and the PVC. This prevents plasticizer migration from the PVC into the bitumen, which can cause embrittlement, and protects the new membrane from bitumen-related chemical attack.
How long does PVC roofing membrane last, and is it UV resistant?
PVC service life depends on the formulation, thickness, exposure, system design, installation quality, and maintenance. UV performance and solar reflectance also vary by formulation and surface color. Request the product-specific TDS and confirm the expected operating conditions before specification.
How do you repair a leaking PVC membrane seam?
PVC membrane seams can be repaired by cleaning the affected area, applying a PVC-compatible solvent cleaner, and hot-air welding a patch of the same material over the damaged seam. The patch must be round-cut at the corners to prevent peeling and should extend at least 75 mm beyond the damaged area in all directions. For extensive seam leakage, a new strip of membrane should be welded over the entire seam line rather than patching individual points.
Ready to Help

Quick Inquiry

Leave a quick message regarding your project needs, and our team will get back to you shortly.

WhatsApp

+86 15263640998