Skip to content
TPO Waterproofing Membrane

TPO Waterproofing Membrane

TPO (Thermoplastic Polyolefin) waterproofing membrane is a hot-air weldable single-ply sheet for roofing systems. Available configurations include homogeneous, fabric-backed and reinforced sheets. Confirm the product-specific thickness, reinforcement, backing and test documentation for the proposed roof assembly. Reflective performance and welding settings must be verified for the supplied product.

Hot-Air WeldableTrial-Weld VerificationWhite Surface Option-40°C FlexibilityH / L / P Types1.2mm / 1.5mm / 2.0mmChlorine-Free & RecyclableOEM Available

Standard Roll Size

Customizable width and length

For project-specific pricing, send your technical requirements and destination port.

Direct Supply OEM Labeling Technical Support

Quick specifications

Standard
GB 27789-2011 / ASTM D6878
Type Options
H (Homogeneous) / L (Fabric-Backed) / P (Reinforced)
Thickness
1.2mm / 1.5mm / 2.0mm
Width
1.0m / 2.0m / 2.5m
Color
White (standard) / Grey / Custom
Low Temp Flexibility
-40°C, no crack
Seam Welding
Hot-air welding; settings established by trial welds
Installation Methods
Mechanically Fastened / Fully Adhered / Ballasted

Available configurations

Select the configuration that matches your substrate, exposure condition and project specification.

Available configurations of TPO Waterproofing Membrane
Configuration Reinforcement Thickness Surface Recommended use
TPO H Homogeneous (H) 1.2mm / 1.5mm / 2.0mm White / Grey / Custom General waterproofing, fabrication, adhered and bonded assemblies
TPO L Fabric-Backed (L) 1.2mm / 1.5mm / 2.0mm White / Grey / Custom Fully adhered systems on insulation or prepared substrates
TPO P Polyester Reinforced (P) 1.2mm / 1.5mm / 2.0mm White / Grey / Custom Mechanically fastened exposed roofs and wind-prone decks

Swipe to view the full table →

Product overview

High-Performance Thermoplastic Polyolefin Roofing Membrane

TPO (Thermoplastic Polyolefin) waterproofing membrane is a single-ply roofing sheet with hot-air welded seams. Select the configuration for the proposed roof assembly and confirm its technical documentation. White surface options require measured reflectance and thermal emittance data; SRI, where specified, is a separate calculated index. Welding settings must be established through trial welds under actual installation conditions.

For projects where a flame-free, self-adhered installation is preferred over mechanical fastening, see our Self-Adhesive Bitumen Membrane. Where a rubber-sheet system with taped or bonded seams is required, compare our EPDM Waterproofing Membrane — and for a polymer sheet with strong chemical resistance, review our PVC Waterproofing Membrane.

TPO Type Selection Guide — H, L, or P?

Selecting the right TPO type is the most important specification decision:

Type H — Homogeneous

Best for general waterproofing and fabrication.

Tensile: ≥ 12.0 MPa
Elongation: ≥ 500%

Type L — Fabric-Backed

Designed for direct bonding to substrates.

Max Tension: ≥ 200 N/cm
Low-temp: -40°C

Type P — Reinforced

Polyester reinforced for mechanically fastened roofs.

Max Tension: ≥ 250 N/cm
Tear: ≥ 450 N

Applications

Commercial Low-Slope Roofing

A single-ply option for offices, retail and institutional roofs. Verify the proposed assembly and any required cool-roof test results against the project requirements; membrane color alone does not establish compliance or energy savings.

Industrial & Warehouse Roofing

Large-span industrial decks are mechanically fastened with P-type TPO (≥ 250 N/cm max tension), delivering wind-uplift resistance and fast installation without open flames — a key advantage over torch-applied systems on occupied or fire-sensitive plants.

Cold Storage & Refrigerated Facilities

The -40°C low-temperature flexibility and plasticizer-free matrix suit cold rooms, freezer plants, and logistics hubs, where PVC-type sheets can stiffen or lose plasticizer over time at sustained low temperatures.

Roof Renovation & Re-cover Systems

Lightweight TPO re-cover systems can be laid over existing membranes after surface preparation, avoiding tear-off costs and roof downtime. Hot-air welded seams keep the retrofit fully watertight without bitumen kettles or torches.

Key benefits

Homogeneous Seam Fusion

Hot-air welding fuses the sheet into one continuous surface. GB 27789 joint peeling strength is ≥ 4.0 N/mm — the seam performs as part of the membrane, not as a weak line.

Installation Flexibility

Mechanically fastened, fully adhered, and ballasted assemblies are all supported. The same H/L/P product family covers exposed roofs, bonded systems, and protected membranes.

Plasticizer-Free Aging

With no migrating plasticizers, the sheet does not shrink, harden, or become brittle as it ages. Dimensional stability under heat aging (≤ 1.0% change) keeps fasteners and seams under control.

Recycling-Compatible Material

The halogen-free polyolefin formulation is compatible with polyolefin recycling streams, supporting EPD documentation and LEED / BREEAM material credit objectives where product documentation is available.

Technical specifications

TPO, Type P (Reinforced), 1.5mm, White Surface (Representative Configuration)

Technical specifications of TPO Waterproofing Membrane
Test Item Unit Test Method Requirement Result / Notes
Tensile Strength (H type) MPa GB 27789 ≥ 12.0 14.0+
Elongation at Break (H) % GB 27789 ≥ 500 600%+
Max Tension (L type) N/cm GB 27789 ≥ 200 ≥ 200
Max Tension (P type) N/cm GB 27789 ≥ 250 ≥ 250
Tear Strength (P type) N GB 27789 ≥ 450 ≥ 450
Watertightness MPa GB 27789 0.3 MPa, 2h No Leakage
Low Temp Bending °C GB 27789 -40°C No crack Typical value; confirm with the product TDS
Joint Peeling Strength N/mm GB 27789 ≥ 4.0 ≥ 4.5
Solar Reflectance (White) Dimensionless fraction Confirm the test method in the product report As specified by the project Request product-specific measured results
Dimensional Change (Heat Aging) % GB 27789 ≤ 1.0 Typical value; confirm with the product TDS

Swipe to view the full table →

Values shown apply to the stated product configuration. Other types (H / L / P), thicknesses (1.2mm / 1.5mm / 2.0mm), colors, and reinforcement options may have different performance values. GB 27789-2011 is the current edition; confirm the applicable product TDS and batch test report before specification or procurement.

Global standard alignment

Cross-reference for engineering specifications & global procurement

Global standard alignment of TPO Waterproofing Membrane
Property China (GB) USA (ASTM) Europe (EN)
Tensile Strength ≥ 12.0 MPa (H) ASTM D6878 EN 13956
Low Temp Flexibility -40°C Reference value; confirm with the product TDS EN 495-5
Joint Peeling Strength ≥ 4.0 N/mm ASTM D6878 EN 12316-2
Compliance Status GB 27789-2011 Equivalent Equivalent

Swipe to view the full table →

* Technical Note: The values shown are reference information for the selected product configuration. Confirm the applicable standard, test method, certification scope, and product-specific documentation with our technical team before specification.

Installation guide

View documents ↓

Base Course Preparation

Ensure the substrate is smooth, dry, clean, and structurally sound. Remove sharp projections and standing water.

Layout & Pre-Paving

Mark reference lines according to the roof layout plan. Pre-pave the TPO membrane and allow it to relax.

Mechanical Fastening

Secure the membrane at the overlap area using approved fastening components (screws and plates).

Hot-Air Seam Welding

Using calibrated hot-air welding equipment, weld all overlapping seams. A continuous bead of molten material should be visible at the edge.

Packaging & OEM

Roll & Pallet Protection

TPO rolls are wound on rigid cores, wrapped in protective film, and secured on fumigated pallets with corner protectors and strapping. The film shields the polyolefin surface from UV and abrasion during ocean transit.

OEM Roll Configuration

Roll width, length, and color are configurable at production. Custom core labels and branded packaging are supported for distributor and contractor programs.

Storage Recommendations

Store rolls upright in original packaging, indoors, away from direct sunlight, heat sources, and sharp objects. Extended outdoor exposure of unpacked rolls can affect surface appearance and weldability; keep storage under cover.

Export Loading Reference
Roll Size (Typical)
2.0m × 20m = 40 m²/roll (width and length customizable)
1.2mm — 20FT Container
Approx. 4,000–5,500 m²
1.5mm — 20FT Container
Approx. 3,500–4,500 m²
2.0mm — 20FT Container
Approx. 2,500–3,500 m²
Note
Estimates based on typical roll dimensions and weight; final loading depends on width, length, reinforcement type, pallet configuration, and destination-country weight limits.

Ordering information

Export Supply Reference
MOQ
1 × 20FT container per specification. Mixed container loading available.
Sample
Sample availability, format, and courier arrangements depend on the selected configuration and destination.
Production Schedule
Confirmed after specification, quantity, packaging, and deposit requirements are reviewed.
Payment Terms
T/T 30% advance, 70% against B/L copy.
Loading Port
Qingdao, China
Documents
TDS, MSDS, Packing List, Certificate of Origin
Inspection
Factory QC + third-party inspection available on request
OEM Service
Color selection (white / grey / custom), thickness (1.2–2.0mm), width (1.0–2.5m), and roll-length customization with branded core sleeves and private-label packaging.

Technical downloads

TPO Technical Data Sheet (TDS)

Request via contact form

Request PDF

TPO Welding & Installation Guide

Request via contact form

Request PDF

Related product

Frequently asked questions

What is the difference between TPO Type H, L, and P?
Type H (homogeneous) is the general-purpose sheet for waterproofing and fabrication — tensile ≥ 12.0 MPa, elongation ≥ 500%. Type L has a textile backing for direct bonding to substrates — max tension ≥ 200 N/cm. Type P is polyester-reinforced for mechanically fastened exposed roofs — max tension ≥ 250 N/cm and tear strength ≥ 450 N. Select by attachment method: H for adhered/fabricated details, L for bonded systems, P for mechanically fastened decks.
What is the solar reflectance of white TPO?
Request the measured solar reflectance and thermal emittance for the exact membrane, color and test condition. If SRI is required, request that result separately with its calculation method. Solar reflectance and SRI are different metrics; a reflectance fraction such as 0.85 must not be reported as SRI.
What temperature is used for TPO hot-air welding?
Temperature, speed and airflow depend on the supplied membrane, thickness, equipment, substrate and weather. Follow the installation instructions and establish settings by trial welds under actual conditions. Carry out the specified seam inspection and testing; appearance alone does not establish seam quality.
Is TPO better than PVC for roofing?
Neither material is best for every roof. Compare the specific membrane and complete assembly against chemical exposure, attachment, substrate compatibility, reflective performance and required documentation. PVC and TPO require compatible welded accessories and must not be welded directly to each other.
What thickness should I choose?
1.2mm is common for general and adhered applications, 1.5mm is the industry standard for mechanically fastened exposed roofs, and 2.0mm is specified for heavy-traffic or ballasted assemblies. Thicker sheets improve puncture resistance but add cost and roll weight — 1.5mm is the value-optimal default for most commercial projects.
How long does TPO membrane last?
Industry typical design service life for TPO roofing is 20 to 30 years, driven by membrane thickness, surface color, installation quality, and climate. White surfaces age better than dark ones because lower surface temperature slows polymer degradation. Confirm the warranty period and service-life documentation for the specific formulation before specification.
Can TPO be installed without an open flame?
Yes — this is one of TPO's key safety advantages. All seams are fused with hot-air welding equipment and the membrane is secured by mechanical fastening or adhesive. There is no torch work, so TPO can be installed on fire-sensitive, occupied, or combustible-adjacent buildings where torch-applied systems are restricted.
Ready to Help

Quick Inquiry

Leave a quick message regarding your project needs, and our team will get back to you shortly.

WhatsApp

+86 15263640998

Email Inquiry