Metro & Tunnel Infrastructure
The global standard for underground transit systems and deep tunnels where high elasticity and permanent water pressure resistance are non-negotiable engineering requirements.
Factory Direct Supply
TY-SHIELD™ SBS (Styrene-Butadiene-Styrene) modified bitumen waterproofing membrane for cold-climate roofing, basements, foundations, tunnels, and infrastructure. Available in polyester (PY), glass fiber (G), and glass-reinforced polyester (PYG) reinforcement, with PE film, fine sand, mineral granules, or aluminum foil surfaces across 3mm, 4mm, and 5mm thicknesses. Standard references and product documentation depend on the selected configuration; confirm the applicable TDS before specification.
Reinforcement Options
PY (Polyester) | G (Glass Fiber) | PYG (Glass Fiber Reinforced Polyester)
Standard Roll Size
1m × 10m | Customizable available
For project-specific pricing, send your technical requirements and destination port.
Direct Answer: For cold climates (below -20°C) and heavy civil infrastructure, specify SBS Type II (4mm/5mm) with Polyester (PY) reinforcement. Based on 2026 factory performance benchmarks, SBS Type II maintains full flexibility down to -25°C, effectively preventing 98% of low-temperature cracking in high-altitude or refrigerated projects.
| Comparison Feature | Standard SBS (Type I) | TY-SHIELD™ SBS II (High Spec) |
|---|---|---|
| Low Temp Flexibility | -15°C to -20°C | -25°C (Guaranteed) |
| Tensile Strength | ≥ 500 N/50mm | ≥ 800-900 N/50mm |
| Heat Resistance | 90°C | 105°C |
Looking for the latest SBS membrane price? As a direct manufacturer, our wholesale rates vary based on current bitumen market indices and your specific project configuration.
Factor 01
Thickness (3mm-5mm)
Factor 02
Reinforcement (PY/G)
Factor 03
Order Quantity
* Competitive bulk quotes provided within 2 working hours. Free samples available for project verification.
Tianyuan's SBS Modified Bitumen Membrane is a high-performance rubber-modified system engineered for structures subject to high thermal movement—including metro tunnels, foundations, and cold-region roofing. Available in customizable PY, G, and PYG reinforcement with PE film, sand, or mineral granule surfaces.
Cold Flexibility
Retains elastomeric properties down to -25°C, ensuring reliable sealing in cold climates.
Anti-Cracking
Designed for projects where substrate movement and crack-bridging are critical safety requirements.
New GB Standard
Manufactured per GB/T 18242-2025 (Type II). Batch test reports available for project specification.
Hot Climate or Exposed Roof?
See our APP Modified Bitumen Membrane for 130°C heat resistance.
No Open Flame Allowed?
Check our Self-Adhesive Bituminous Membrane for safe, cold-applied installation.
Contact our export team with your target reinforcement type, thickness, surface finish, performance grade, and destination port. We will confirm the applicable quotation, documentation, sample option, and production schedule.
Select the reinforcement, thickness and surface finish to match your project requirements. Contact us with your specification for a tailored quotation.
| Configuration | Reinforcement | Thickness | Surface | Recommended Use |
|---|---|---|---|---|
| SBS PY PE | Polyester Felt (PY) | 3mm / 4mm / 5mm | PE Film | Basement, foundation, protected roofing |
| SBS PY Mineral | Polyester Felt (PY) | 3mm / 4mm / 5mm | Mineral Granules | Exposed roofing cap sheet |
| SBS G PE | Fiberglass Felt (G) | 3mm / 4mm / 5mm | PE Film | Dimensionally stable multi-layer roof systems. Standard thickness per former GB 18242-2008: 3-4mm; 5mm available on request |
| SBS PYG PE | Composite (PYG) | 3mm / 4mm / 5mm | PE Film / Sand | Mechanically fastened single-layer roofing (legacy GB 18242-2008 classification); project-specific heavy-load systems. Standard thickness per former standard: 5mm; other thicknesses on request |
Swipe to view the full table →
All thicknesses and surface finishes shown are available in standard production. Custom roll dimensions, packaging and private-label printing are available subject to minimum order quantity. Final configuration should be selected according to climate, substrate, waterproofing system design, exposure condition and local project specifications.
The global standard for underground transit systems and deep tunnels where high elasticity and permanent water pressure resistance are non-negotiable engineering requirements.
Specified for large-span industrial roofs in cold climates, where the membrane must survive extreme temperature swings without losing its waterproofing integrity.
Ideal for below-grade applications with significant structural settlement risks, providing a reliable barrier against aggressive groundwater and soil acids.
Achieves superior tensile values (900N+ for Type II) combined with high elongation. This allows the membrane to function as a 'flexible skin' that bridges cracks and absorbs substrate deformation without rupturing.
Maintains its physical properties across a broad temperature spectrum, from -25°C to 105°C. This ensures consistent performance throughout the transition from freezing winters to intense summer sun.
The high-purity bitumen compound is naturally resistant to the acids, alkalis, and salts commonly found in soils and industrial environments, ensuring the membrane's longevity in buried applications.
Fully optimized for precision torching (hot-melt) for maximum security, while remaining compatible with cold-applied adhesives where open flames are restricted, providing flexibility for diverse site conditions.
SBS PY II, 4mm, PE Film Surface (Representative Configuration)
| Test Item | Unit | Test Method | Requirement | Result / Notes |
|---|---|---|---|---|
| Soluble Content (3mm) | g/m² | GB/T 18242 | ≥ 2,100 | ≥ 2,100 |
| Soluble Content (4mm) | g/m² | GB/T 18242 | ≥ 2,900 | ≥ 2,900 |
| Soluble Content (5mm) | g/m² | GB/T 18242 | ≥ 3,500 | ≥ 3,500 |
| Tensile Strength — Peak (PY Type II) | N/50mm | GB/T 18242 | ≥ 800 | 900+ |
| Tensile Strength — Peak (PYG Type II) | N/50mm | GB/T 18242 | ≥ 900 | Typical value; confirm with the product TDS |
| Elongation at Peak (PY Type II) | % | GB/T 18242 | ≥ 40 | 40–50% |
| Heat Resistance (Type I) | °C / 2h | GB/T 18242 | 90°C, ≤ 2mm slip | No flow or drip |
| Heat Resistance (Type II) | °C / 2h | GB/T 18242 | 105°C, ≤ 2mm slip | No flow or drip |
| Low Temp Flexibility (Type II) | °C | GB/T 18242 | -25°C — No crack | No crack |
| Watertightness (PY) | MPa / min | GB/T 18242 | 0.3MPa, 30min | Impermeable |
| Seam Peeling Strength | N/mm | GB/T 18242 | ≥ 1.5 | ≥ 1.5 |
| Mass Gain After Water Immersion (PE/S) | % | GB/T 18242 | ≤ 1.0 | Typical value; confirm with the product TDS |
Swipe to view the full table →
Values shown apply to the stated product configuration. Other reinforcement types (PY / G / PYG), thicknesses (3mm / 4mm / 5mm), surface materials (PE / S / M / ALU), and performance grades (Type I / II) may have different performance values. Technical values reference the former GB 18242-2008 requirements; the current edition is GB/T 18242-2025 (effective 2026-05-01). Request the corresponding TDS and batch test report before specification or procurement.
Cross-reference for engineering specifications & global procurement
| Property | China (GB) | USA (ASTM) | Europe (EN) |
|---|---|---|---|
| Tensile Strength | ≥ 800 N/50mm | ASTM D6164 | EN 12311-1 |
| Low Temp Flexibility | -25°C | Reference value; confirm with the product TDS | Reference value; confirm with the product TDS |
| Heat Resistance | 90°C / 105°C | ASTM D5147 | EN 1110 |
| Compliance Status | GB/T 18242 | Equivalent | Equivalent |
Swipe to view the full table →
* Technical Note: The values shown are reference information for the selected product configuration. Confirm the applicable standard, test method, certification scope, and product-specific documentation with our technical team before specification.
Ensure the substrate is dry, clean, smooth, and free from dust, oil, and loose particles. Fill cracks and surface irregularities with polymer mortar. Concrete surfaces should be fully cured.
Apply bitumen primer evenly and completely over all surfaces to be waterproofed. Allow the primer to dry fully before membrane installation — this ensures maximum adhesion between the substrate and the torch-applied membrane.
Use the torch application (hot-melt) method: heat the lower PE film and bitumen coating with a controlled propane flame until the bitumen melts uniformly. Roll the membrane forward with steady pressure. For projects where open flame is restricted, cold-bonding adhesives are fully compatible.
Maintain a minimum 100mm longitudinal lap and 150mm end lap. Roll all seams firmly to squeeze out a small bead of molten bitumen — this confirms a continuous, monolithic seal. On vertical surfaces, fix with metal battens and seal with compatible sealant.
Rolls are secured vertically on fumigated wooden pallets, wrapped in high-density polyethylene film with corner protectors and heavy-duty strapping for safe ocean freight transit.
Full private label support including custom-printed wrapping film, branded core sleeves, pallet labels, and outer-package markings for wholesale and distribution partners.
Store rolls vertically in original packaging in a dry, ventilated area below 50°C. Avoid direct sunlight and rain exposure. Shelf life: 12 months under standard conditions.
Ready for PDF Request
Ready for PDF Request
Deep dive into polymer-modified bitumen technology, international standards, and global market trends with our expert technical series.
Leave a quick message regarding your project needs, and our team will get back to you shortly.
+86 15263640998
Email Inquiry