Skip to content
Self-Adhesive Bitumen Flashing Tape

Self-Adhesive Bitumen Flashing Tape

Cold-applied, aluminum-faced modified-bitumen flashing tape for roof edges, metal-to-masonry transitions, gutters and selected repair details. Quote by facing, substrate, width, thickness and roll length.

Bitumen Flashing TapeAluminum-FacedRoof & Gutter DetailsCold-AppliedBulk Roll Supply

Tape Build

Aluminum-faced bitumen strip

Primary Detail

Roof flashings and gutters

Reference

JC/T 1070-2008

For project-specific pricing, send your technical requirements and destination port.

Direct Supply OEM Labeling Technical Support

Quick specifications

Tape Build
Aluminum-faced polymer-modified bitumen with removable release liner
Order Thicknesses
1.0 / 1.2 / 1.5 mm quotation options
Order Widths
50 / 75 / 100 / 150 / 200 / 300 mm quotation options
Roll Lengths
5 / 10 / 20 m; confirm each width-thickness-length combination
Facing
Aluminum foil; color and reinforcement by approved order sample
Reference Standard
JC/T 1070-2008 classification and test items for self-adhering bituminous flashing strips
Metal Peel Index
≥1.5 N/mm on aluminum plate at standard test conditions
Water Impermeability Index
0.2 MPa for 120 min: no leakage

Product overview

Aluminum-Faced Bitumen Flashing for Defined Roof Details

This self-adhesive bitumen flashing tape is supplied as a faced strip, rather than a full-width waterproofing membrane or an unfaced joint filler. Its modified-bitumen adhesive is protected by a removable liner until installation; the aluminum surface remains visible in the selected roof or gutter detail.

For procurement, compare the complete construction of each roll: facing, adhesive thickness, width, length and substrate. The technical indices above can be specified for a project, while the offered grade and its test record should match the final order. The −20°C bend check and heat test describe laboratory performance, not a blanket site-application temperature or service-life promise.

When the work involves a large roof area, specify the primary waterproofing membrane and use flashing tape where the system detail calls for it. For coated metal, old bitumen and porous mineral substrates, approve a representative sample before placing the bulk order.

Applications

Roof Edges and Flashings

Form a narrow, faced waterproofing detail at selected roof edges, upstands, rooflights and parapet junctions, with terminations integrated into the roof system.

Gutters and Downpipes

Patch localized seams or penetrations on sound metal gutters and downpipes after cleaning, drying and checking the required overlap.

Metal-to-Masonry Transitions

Bridge specified junctions between sheet metal and prepared masonry or concrete, using compatible primer on porous surfaces where the project trial calls for it.

Compatible Bitumen-Roof Repairs

Use as a repair strip on suitable existing bituminous surfaces after removing loose granules, dirt and degraded material and confirming adhesion on site.

Key benefits

Aluminum Face for Exposed Details

The protective top layer separates the bitumen adhesive from direct contact and defines the appearance of an exposed repair. Confirm facing grade and exposure conditions for the order.

Flame-Free Placement

A removable liner allows the strip to be positioned and pressure-bonded without torching the tape. Substrate preparation and rolling still control the finished seal.

Dimensioned Repair Coverage

Select tape width to cover the defect plus a sound margin on each side. The correct width depends on the detail drawing and substrate, not a universal overlap figure.

Procurement-Ready Roll Schedule

Confirm facing, roll dimensions, color, carton quantity and label artwork together so bulk quotations and delivery checks are comparable.

Technical specifications

Aluminum-faced modified-bitumen flashing strip — project specification indices

Technical specifications of Self-Adhesive Bitumen Flashing Tape
Test Item Unit Test Basis / Condition Project Index
Nominal thickness mm Excluding release liner 1.0 / 1.2 / 1.5
Roll width mm Selected order size 50 / 75 / 100 / 150 / 200 / 300
Roll length m Selected order size 5 / 10 / 20
Peel strength N/mm Aluminum plate; 23°C test ≥1.5
Water impermeability — 0.2 MPa for 120 min No leakage
Low-temperature flexibility — −20°C bend test No cracking
Heat resistance — 75°C for 24 h, vertical aluminum plate Assess sliding and face condition

Swipe to view the full table →

Installation guide

View documents ↓

Confirm the Repair Detail

Measure the sound bonding area around the joint or defect. Choose width, thickness and facing for the detail; do not use a narrow strip as a substitute for a full roof membrane.

Prepare and Trial the Substrate

Remove rust, dust, oil, loose coatings and standing water. Dry the base. Trial adhesion on painted metal, aged bitumen, masonry or plastic, and use a compatible primer if required.

Cut, Position and Roll

Cut without damaging the foil, peel the liner progressively, and press from the center toward the edges. Use a seam roller to remove trapped air and make continuous contact.

Finish Edges and Inspect

Check overlaps, edges, corners and terminations against the project drawing. Protect the patch from traffic or mechanical damage and inspect representative adhesion.

Roll Supply & Documents

Bulk Roll & Carton Schedule

Specify thickness, width, length, foil finish, color, rolls per carton and destination port. Agree palletization and private-label artwork against an approved sample.

Technical Documents & Samples

Request the offered grade's TDS, SDS, substrate test and facing sample. State whether the tape will be exposed, overlaid or used on an existing bitumen roof.

Technical downloads

Bitumen Flashing Tape TDS

Request via contact form

Request PDF

Flashing Tape Application Guide

Request via contact form

Request PDF

Related product

Frequently asked questions

How is this different from butyl sealing tape?
This page covers an aluminum-faced modified-bitumen flashing strip. Butyl tape has a different adhesive base. Choose by roof system, substrate, facing and required test record rather than treating the tapes as direct substitutes.
Can the tape remain exposed on a roof?
An aluminum face can protect the adhesive at selected exposed details. Confirm the offered facing, service conditions, edge treatment and project approval before specifying permanent exposure.
Will it bond to old asphalt felt or coated steel?
It can be considered on sound, prepared bituminous or metal surfaces. Remove loose material and run a substrate-specific adhesion trial; primer and compatibility requirements vary.
Does the −20°C bend index mean installation at −20°C?
No. It is a laboratory flexibility condition. Application temperature is a separate requirement and must be checked for the supplied grade and site substrate.
What details are needed for a wholesale quotation?
Send the detail drawing or repair location, substrate, exposure condition, thickness, width, roll length, foil finish, total roll quantity, carton or label requirements and destination port.
Ready to Help

Quick Inquiry

Leave a quick message regarding your project needs, and our team will get back to you shortly.

WhatsApp

+86 15263640998

Email Inquiry