Roof Edges and Flashings
Form a narrow, faced waterproofing detail at selected roof edges, upstands, rooflights and parapet junctions, with terminations integrated into the roof system.
Cold-applied, aluminum-faced modified-bitumen flashing tape for roof edges, metal-to-masonry transitions, gutters and selected repair details. Quote by facing, substrate, width, thickness and roll length.
Tape Build
Aluminum-faced bitumen strip
Primary Detail
Roof flashings and gutters
Reference
JC/T 1070-2008
For project-specific pricing, send your technical requirements and destination port.
This self-adhesive bitumen flashing tape is supplied as a faced strip, rather than a full-width waterproofing membrane or an unfaced joint filler. Its modified-bitumen adhesive is protected by a removable liner until installation; the aluminum surface remains visible in the selected roof or gutter detail.
For procurement, compare the complete construction of each roll: facing, adhesive thickness, width, length and substrate. The technical indices above can be specified for a project, while the offered grade and its test record should match the final order. The −20°C bend check and heat test describe laboratory performance, not a blanket site-application temperature or service-life promise.
When the work involves a large roof area, specify the primary waterproofing membrane and use flashing tape where the system detail calls for it. For coated metal, old bitumen and porous mineral substrates, approve a representative sample before placing the bulk order.
Form a narrow, faced waterproofing detail at selected roof edges, upstands, rooflights and parapet junctions, with terminations integrated into the roof system.
Patch localized seams or penetrations on sound metal gutters and downpipes after cleaning, drying and checking the required overlap.
Bridge specified junctions between sheet metal and prepared masonry or concrete, using compatible primer on porous surfaces where the project trial calls for it.
Use as a repair strip on suitable existing bituminous surfaces after removing loose granules, dirt and degraded material and confirming adhesion on site.
The protective top layer separates the bitumen adhesive from direct contact and defines the appearance of an exposed repair. Confirm facing grade and exposure conditions for the order.
A removable liner allows the strip to be positioned and pressure-bonded without torching the tape. Substrate preparation and rolling still control the finished seal.
Select tape width to cover the defect plus a sound margin on each side. The correct width depends on the detail drawing and substrate, not a universal overlap figure.
Confirm facing, roll dimensions, color, carton quantity and label artwork together so bulk quotations and delivery checks are comparable.
Aluminum-faced modified-bitumen flashing strip — project specification indices
| Test Item | Unit | Test Basis / Condition | Project Index |
|---|---|---|---|
| Nominal thickness | mm | Excluding release liner | 1.0 / 1.2 / 1.5 |
| Roll width | mm | Selected order size | 50 / 75 / 100 / 150 / 200 / 300 |
| Roll length | m | Selected order size | 5 / 10 / 20 |
| Peel strength | N/mm | Aluminum plate; 23°C test | ≥1.5 |
| Water impermeability | — | 0.2 MPa for 120 min | No leakage |
| Low-temperature flexibility | — | −20°C bend test | No cracking |
| Heat resistance | — | 75°C for 24 h, vertical aluminum plate | Assess sliding and face condition |
Swipe to view the full table →
Measure the sound bonding area around the joint or defect. Choose width, thickness and facing for the detail; do not use a narrow strip as a substitute for a full roof membrane.
Remove rust, dust, oil, loose coatings and standing water. Dry the base. Trial adhesion on painted metal, aged bitumen, masonry or plastic, and use a compatible primer if required.
Cut without damaging the foil, peel the liner progressively, and press from the center toward the edges. Use a seam roller to remove trapped air and make continuous contact.
Check overlaps, edges, corners and terminations against the project drawing. Protect the patch from traffic or mechanical damage and inspect representative adhesion.
Specify thickness, width, length, foil finish, color, rolls per carton and destination port. Agree palletization and private-label artwork against an approved sample.
Request the offered grade's TDS, SDS, substrate test and facing sample. State whether the tape will be exposed, overlaid or used on an existing bitumen roof.
Request via contact form
Request via contact form
Leave a quick message regarding your project needs, and our team will get back to you shortly.
+86 15263640998
Email Inquiry