Asphalt Shingle Underlayment
Used over suitable roof decking beneath asphalt shingles as a secondary water-shedding layer. Fastening, laps and exposure limits must follow the selected roofing system and applicable local requirements.
Factory Direct Supply
Asphalt-saturated organic roofing felt designed for roof-deck underlayment beneath asphalt shingles and for use as a ply in compatible hot-asphalt roofing or waterproofing assemblies. Tianyuan catalog configurations include 1 m width, 0.5 mm and 0.8 mm thickness options, with grey or black appearance. Exact grade and standard compliance should be confirmed against the current TDS before procurement.
Typical Applications
Shingle underlayment / compatible built-up roofing ply
Standard Roll Size
1 m width; roll length to be confirmed by grade
For project-specific pricing, send your technical requirements and destination port.
Tianyuan's Asphalt Roofing Felt is a professional-grade organic fiber sheet saturated with high-purity asphalt. It serves as the primary secondary water-shedding layer beneath asphalt shingles and as a reliable reinforcing ply in complex built-up roofing (BUR) assemblies.
Organic fiber carrier is saturated through its full thickness for superior rain and moisture resistance.
Available in Type I (15#) and Type II (30#) grades to meet international building codes.
Mechanically fastened or embedded in hot asphalt. No torch, no primer, and zero curing time required.
| Performance Metric | Type I (No. 15) | Type II (No. 30) — Heavy Duty |
|---|---|---|
| Saturated Felt Mass | ≥ 560 g/m² | ≥ 1270 g/m² |
| Breaking Strength (MD) | ≥ 30 lbf/in | ≥ 40 lbf/in |
| Pliability (at 23°C) | No Crack | No Crack |
| Recommended Use | Standard steep-slope roofing | Heavy BUR & long-term exposure |
Installing Asphalt Shingles?
For standard residential projects, Type I (15#) is the most cost-effective choice. It provides sufficient secondary protection without excessive roll weight.
Need Puncture Resistance?
For large-scale industrial projects or multi-layer assemblies, specify Type II (30#). Its increased mass offers better durability against job-site foot traffic.
See the technical specifications, installation guide and packaging sections for full details, or request the TDS and quotation.
Select the reinforcement, thickness and surface finish to match your project requirements. Contact us with your specification for a tailored quotation.
| Configuration | Reinforcement | Thickness | Surface | Recommended Use |
|---|---|---|---|---|
| Organic Felt Underlayment 0.5 | Organic fiber felt | 0.5 mm | Grey / Black | Roof-deck underlayment beneath compatible asphalt shingles or roof coverings |
| Organic Felt Underlayment 0.8 | Organic fiber felt | 0.8 mm | Grey / Black | Roof-deck underlayment or selected compatible asphaltic system applications |
Swipe to view the full table →
All thicknesses and surface finishes shown are available in standard production. Custom roll dimensions, packaging and private-label printing are available subject to minimum order quantity. Final configuration should be selected according to climate, substrate, waterproofing system design, exposure condition and local project specifications.
Used over suitable roof decking beneath asphalt shingles as a secondary water-shedding layer. Fastening, laps and exposure limits must follow the selected roofing system and applicable local requirements.
Selected grades may be incorporated as a reinforcing ply in compatible low-slope built-up roofing systems using the asphalt type and layer configuration specified by the system designer.
The felt may be embedded in compatible hot asphalt as part of a designed multi-layer roofing or waterproofing assembly. It is not a standalone exposed waterproofing membrane.
The organic fiber carrier is passed through molten asphalt and hot-roller extruded so the sheet is impregnated through its full thickness rather than merely coated — the construction described in the Tianyuan product catalog for asphalt roofing felt.
Catalog data groups the felt into Type I (15#) and Type II (30#) performance grades aligned to ASTM D226 requirement levels, with minimum saturated-felt mass of 560 g/m2 and 1270 g/m2 respectively.
Catalog performance data shows max 4.00% loss on heating at 105 degC for 5 h, supporting use in warm export climates when stored and transported per the catalog guidance (below 45 degC, protected from direct sun and rain).
The felt can be mechanically fastened as steep-slope underlayment or embedded in compatible hot asphalt as a built-up roofing ply — no torch, primer or curing time required on site.
Technical properties depend on the selected grade, construction and target standard. Tianyuan catalog data confirms nominal 1 m width, 0.5 mm / 0.8 mm thickness and grey / black configurations, with Type I / Type II performance grades aligned to the ASTM D226 15# / 30# (15 lb / 30 lb) requirement levels shown in the table (D4869-equivalent levels are also available). Grade-specific physical properties should be confirmed against the latest Tianyuan TDS or applicable test report before procurement.
| Test Item | Unit | Test Method | Requirement | Result / Notes |
|---|---|---|---|---|
| Nominal Width | m | Tianyuan product catalog | Catalog configuration | 1.0 |
| Nominal Thickness | mm | Tianyuan product catalog | Catalog configuration | 0.5 / 0.8 |
| Color | — | Tianyuan product catalog | Catalog configuration | Grey / Black |
| Supply Form | — | Tianyuan product catalog | Catalog configuration | Roll |
| Performance Grade | — | Tianyuan product catalog | Type I / Type II | Type I (15#) / Type II (30#) |
| Pliability (23 +/- 2 degC, 90 deg bend) | mm radius | ASTM D226 / D4869 per catalog | No crack | 12.7 |
| Tear Strength (23 +/- 2 degC) | N | ASTM D226 / D4869 per catalog | Min | 2.5 |
| Breaking Strength MD — Type I / Type II | lbf/in | ASTM D226 15# / 30# per catalog | Min | 30 / 40 |
| Breaking Strength CD — Type I / Type II | lbf/in | ASTM D226 15# / 30# per catalog | Min | 15 / 20 |
| Loss on Heating (105 degC, 5 h) | % | ASTM D226 per catalog | Max | 4.00 |
| Net Mass of Saturated Felt — Type I / Type II | g/m2 | ASTM D226 15# / 30# per catalog | Min | 560 / 1270 |
| Saturation — Type I / Type II | % by wt | ASTM D226 15# / 30# per catalog | Min | 120 / 150 |
Swipe to view the full table →
ASTM D226/D226M and ASTM D4869/D4869M are referenced as relevant industry specification frameworks. Mention of these standards does not by itself constitute certification or compliance for every Tianyuan configuration. Confirm the required standard, type, edition, roll configuration and test results before specification or purchase.
Confirm the approved roof system before installation. The roof deck or waterproofing substrate must be structurally sound, smooth, clean and dry. Remove dust, loose material, sharp projections and other contaminants that could create wrinkles, punctures or poor contact.
Install horizontal courses from the lower roof edge upward so successive sheets shed water. Keep the felt smooth and mechanically fasten it in accordance with the roof-covering manufacturer's instructions, project specification and local code.
Where the approved built-up roofing or waterproofing system specifies hot asphalt, prepare the substrate as required, apply the compatible asphalt compound and embed the felt while maintaining continuous contact without trapped air. Confirm asphalt type, laps and temperature limits before work.
Asphalt-saturated felt is an underlayment or system ply, not a permanent exposed roof covering. Minimize unnecessary exposure and complete the specified roofing or waterproofing assembly as soon as practical.
Rolls can be supplied with protective plastic film. Final roll dimensions, wrapping and labeling should be confirmed for the selected grade before shipment.
Store rolls in a dry, ventilated location protected from direct sunlight, rain and other weather exposure. Follow the current product storage instructions for the selected grade.
Keep different product types and sizes separated and protect rolls from crushing, leaning and side pressure. Confirm the approved stacking method before storage.
Protect rolls from rain, direct sun and mechanical damage during loading and transportation. Use additional protective covering where required.
Ready for PDF Request
Ready for PDF Request
Deep dive into polymer-modified bitumen technology, international standards, and global market trends with our expert technical series.
Leave a quick message regarding your project needs, and our team will get back to you shortly.
+86 15263640998